S/HS/Duet Universal-Wedge Quick Start Guide
Indicators
SCANNER PROGRAMMING MODE
SETTING LABEL I.D.
Label identifiers consist of one or two ASCII
characters that can precede or follow barcode label
data as it is transmitted to the host. The host uses
these characters as a means of distinguishing
between symbologies.
The established industry standards used are sym-
bology-specific label identifiers, and are listed in
the table below.
UPC-A .......................... 'A' EAN-8 (5 Add-on) ......... 'FF'
UPC-E .......................... 'E' EAN-8 (8 Add-on) .......... 'FF'
EAN-8........................... 'FF' EAN-13 (2 add-on) ......... 'F'
EAN-13......................... 'F' EAN-13 (5 Add-on) ......... 'F'
UPC-A (2 add-on) ....... 'A' EAN-13 (8 Add-on) .......... 'F'
UPC-A (5 Add-on)....... 'A' Code 39.......................... '*'
UPC-A (8 Add-on)....... 'A' Codabar ..................... '%'
UPC-E (2 add-on) ....... 'E' Interleaved.2 of 5............. 'i'
UPC-E (5 Add-on)....... 'E' Code 93..................... '&'
UPC-E (8 Add-on)....... 'E' Code 128 ......................... '#'
EAN-8 (2 add-on) ....... 'FF' MSI/Plessey .................. '@'
NOTE
Enabling Label I.D's to be transmitted will not allow programming
of the Wedge. You must disable Label I.D. (If previously enabled)
before programming the Wedge Interface.