EAN-8
Product Reference Guide
5-13
EAN-8 — continued
Expand EAN-8 to EAN-13—
Expands EAN-8 data to the EAN-13 data format. Selecting
this feature also changes the symbology ID to match those required for EAN-13.
Minimum Reads
This feature specifies the minimum number of consecutive times an EAN-8 label must be
decoded before it is accepted as a good read.
START / END
PROGRAMMING BAR CODES
Don’t Expand to EAN-13
DEFAULT
Expand to EAN-13
START / END
PROGRAMMING BAR CODES
Minimum = 1 Read
DEFAULT
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads