1-8 Magellan
TM
8500Xt Scanner
Warm-Up Time
There are two pertinent warm-up times that apply to the scanning-scale:
NOTE
The two warm-up periods can be performed concurrently, thereby reducing
the total required warm-up time to 60 minutes.
Thermal Equilibrium
When the unit is moved from a cooler temperature (such as a storage area)
to a warmer environment (such as a checkstand location), 60 minutes
must be allowed to acclimate the unit to ambient conditions prior to cali-
bration or operation.
Power-up
Once installed and powered up, a warm-up time of 15 minutes must be
allowed before calibrating or performing weighing operations.
User Configurable Warm-up
The user may configure the unit for a pre-programmed warm-up time
that is activated every time the scanner is powered up. During this time,
the scale is viewed by the POS terminal as off-line.
NOTE
Contact Technical Support to learn more about this advanced programmable
feature.