Psc Handheld Laser Bar Code Scanners Keyboard Wedge / Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Skanery Psc Handheld Laser Bar Code Scanners Keyboard Wedge / . PSC Handheld Laser Bar Code Scanners Keyboard Wedge / Wand Emulation Interface User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 88
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
User’s / Programming Guide
Handheld Laser Bar Code Scanners
Keyboard Wedge /
Wand Emulation Interface
Przeglądanie stron 0
1 2 3 4 5 6 ... 87 88

Podsumowanie treści

Strona 1 - User’s / Programming Guide

User’s / Programming GuideHandheld Laser Bar Code ScannersKeyboard Wedge / Wand Emulation Interface

Strona 2 - Disclaimer

2 User’s / Programming GuideUnpackingYour package should include a scanner, interface cable, User’s Man-ual, and a plastic scanner holder.The unit sho

Strona 3

06656 3Connecting the Power SupplyIf supplied, plug the connector from the external power supply into the

Strona 4

4 User’s / Programming GuideSerial CommunicationsThe PSC scanner provides the user with two different serial commu-nications options: Serial TTL and

Strona 5 - Table of Contents

06656 5AutoSense® OperationAutoSense® is a factory installed feature requested at time of order. It provid

Strona 6

6 User’s / Programming GuideNO Enable AutoSense®NN Disable AutoSense®To use this mode of operation properly, the user must first attach the plastic sc

Strona 7 - 06656 iii

06656 7Wand Emulation OperationTo operate the PSC scanner in Wand Emulation the user must first turn off t

Strona 8

8 User’s / Programming GuideSetup OverviewGeneral setup parameters are divided into Keyboard Wedge options (communication to host through the terminal

Strona 9 - Introduction

06656 9Data Synchronization• Disable Data Synchronization• Enable Data Synchronization• Active Polarity Hi

Strona 10 - Installation

10 User’s / Programming GuideSymbologiesThe bar codes that can be read by PSC’s bar code scanners include:Code 39 Code 93Interleaved 2 of 5 Code 128St

Strona 11 - 3

06656 11Parameters Selection GuidelinesThree basic steps must be followed when selecting parameters for yo

Strona 12 - Serial Communications

PSC Inc959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140An Unpublished Work - All rights reserved. No part of the c

Strona 13 - Operation

12 User’s / Programming Guide1. Scan the bar code beside Intercharacter Delay = XX and lis-ten for one short-high beep.2. After the beep, scan the b

Strona 14 - 6 User’s / Programming Guide

06656 13Serial CommunicationReset DefaultTo program the communication mode for serial asynchronous com-mun

Strona 15 - Wand Emulation Operation

14 User’s / Programming GuideData TransmissionSerial transmission data is composed of three of four different ele-ments, depending upon host system re

Strona 16 - Setup Overview

06656 15If your system requires a WORD length of 8 bits, 1 or 2 STOP bits, and PARITY check, select the ap

Strona 17 - 9

16 User’s / Programming GuideIf your system requires a WORD length of 8 bits and 1 or 2 STOP bits, but no PARITY, select the option below:PARITY check

Strona 18 - 10 User’s / Programming Guide

06656 17CTS Like XON/XOFF protocol, CTS protocol is a mechanism used to con-trol data flow out. The CTS in

Strona 19 - 11

18 User’s / Programming GuideAnother flow control option is available. If enabled, the stop/go pro-tocol disables the trigger after every successful s

Strona 20 - 12 User’s / Programming Guide

06656 19Label BufferingThe user may select one of three levels of serial buffering. With Full Buffering (t

Strona 21 - Serial Communication

20 User’s / Programming GuideMenu Commands Parameter MessagesIn serial mode, most menu commands when scanned will provide a confirmation message to th

Strona 22 - 14 User’s / Programming Guide

06656 21HF External Trigger(-)General ParametersIntercharacter DelayCertain terminals and computers requir

Strona 23 - 15

Scanners discussed in this manual are covered by patents issues or pending in the U.S. and other countries.NOTICEThe scanner is certified to be a Clas

Strona 24 - 16 User’s / Programming Guide

22 User’s / Programming GuideTransmission ModeFull Duplex or Half Duplex Transmission mode selects either full or half duplex operation regard-less of

Strona 25 - 17

06656 23ZB Display ConfigurationWhen Option ZC is scanned, the program version followed by car-riage retur

Strona 26 - 18 User’s / Programming Guide

24 User’s / Programming GuideBE Enable 4 Times Laser RedundancyLaser TimeoutThe scan beam will activate in response to a trigger pull. The beam will a

Strona 27 - 19

06656 25AC Beeper On; Volume MediumAD Beeper On; Volume Loud *#@ Message FormattingMessage formatting desc

Strona 28 - 20 User’s / Programming Guide

26 User’s / Programming GuidePrefixA prefix is a subset of the preamble normally formatted to some industry standard, i.e., it is represented by a spe

Strona 29 - General Parameters

06656 27MF Suffix = CR and LF *Users also have the ability to select any ASCII character for use as a suff

Strona 30 - 22 User’s / Programming Guide

28 User’s / Programming GuideCode IdentifierA code identifier may optionally be transmitted with the message. This option is provided so a host comput

Strona 31 - 23

06656 29Preamble or Postamble SelectionPreambles and Postambles are composed of up to four ASCII charac-te

Strona 32 - 24 User’s / Programming Guide

30 User’s / Programming GuideLA Postamble = None*#LB Enter PostambleIMPORTANTScan Enter Postamble to enter a Postamble, then refer to the Hexadecimal

Strona 33 - Message Formatting

06656 31Serial CommandsGeneral Serial Command FormatSerial Commands are only accepted by the PSC scanner w

Strona 35 - 27

32 User’s / Programming GuideBeeper Off CR-LF AckIf the scanner receives an unknown or improperly formatted code, or if the required parameters are mi

Strona 36 - 28 User’s / Programming Guide

06656 33Power Standby and Serial CommandsWhen the scanner is programmed for standby power operation (@B),

Strona 37 - 29

34 User’s / Programming GuideKeyboard Wedge ParametersScan symbol CE to enable Keyboard Wedge mode. Next, select a ter-minal type by scanning the symb

Strona 38 - 30 User’s / Programming Guide

06656 35CT IBM 319X – U.S.A.CY PS/2 Mode 57/25 — U.S.A.C6 Unisys B-26C8 Link 125CV PC-AT German KeyboardCW

Strona 39 - Serial Commands

36 User’s / Programming Guide\E PC-AT Italian Keyboard\F PC-AT Spanish Keyboard\G PC-AT Swedish Keyboard\H PC-AT Portuguese KeyboardIn normal Wedge Mo

Strona 40 - 32 User’s / Programming Guide

06656 37EO Shift Alphabetic CharactersEP Normal Alphabetic Characters*CQ Enable Primary Keyboard@CR Enable

Strona 41 - 33

38 User’s / Programming GuideSymbologiesThe PSC scanner is configured with Code 39, Code 128, UPC-A and UPC-E not expanded symbologies. The user has t

Strona 42 - Keyboard Wedge Parameters

06656 39Option QB or Option QC enable both UPC-A and UPC-E. If UPC is enabled, any UPC label, with or with

Strona 43 - 35

40 User’s / Programming GuideTransmission of the last character in a UPC symbol (the check digit) is disabled by scanning Option QF, or is enabled by

Strona 44 - 36 User’s / Programming Guide

06656 41QSEnable transmissionof UPC-E check digit*QTDisable transmission of UPC-E number system digitQUEna

Strona 45 - 37

06656 iTable of ContentsIntroductionKeyboard Wedge Mode ... 1Serial Communications Mode ...

Strona 46 - Symbologies

42 User’s / Programming GuideEAN/JANScan Option RA to disable EAN/JAN (8 or 13 digit).Option RB or RC enables both EAN 8 digit and EAN 13 digit. If EA

Strona 47 - 39

06656 43Transmission of the last character in an EAN/JAN symbol (the check digit) is disabled by scanning

Strona 48 - 40 User’s / Programming Guide

44 User’s / Programming GuideCode 39To disable Code 39, scan Option OA.OA Disable Code 39To enable Code 39, scan Option OB or OC. After enabling Code

Strona 49 - 41

06656 45The minimum length of Code 39 messages is set by scanning Option OH, followed by scanning two digi

Strona 50 - 42 User’s / Programming Guide

46 User’s / Programming GuideCode 2 of 5 – InterleavedScan Option PA to disable Interleaved Code 2 of 5.Scan Option PB or PC to enable Interleaved Cod

Strona 51 - 43

06656 47Code 2 of 5 – StandardScan Option PF to disable Standard Code 2 of 5.PF Disable Standard Code 2 of

Strona 52 - 44 User’s / Programming Guide

48 User’s / Programming GuideCode 128Scan Option TA to disable Code 128.TA Disable Code 128Scan Option TB to enable Code 128.TB Enable Code 128 *#@The

Strona 53 - 45

06656 49The minimum length of Codabar messages is set by scanning Option VE, followed by scanning two digi

Strona 54 - Code 2 of 5 – Interleaved

50 User’s / Programming GuideMSI/PlesseyPrevious customization of other scanner features may have made MSI/Plessey unavailable in some scanners. Consu

Strona 55 - Code 2 of 5 – Standard

06656 51Code 93Previous customization of other scanner features may have made Code 93 unavailable in some

Strona 56 - Code 128

ii User’s / Programming GuideSystem Status ... 22Power Consumption ...

Strona 57 - 49

52 User’s / Programming GuideUD Enable Full ASCII Code 93UA Disable Code 9316KTF Enable 16K CodeTE Disable 16K CodeUESet Minimum Length, specified by

Strona 58 - MSI/Plessey

06656 53Digit Selection 5 0 6 1 7 2 8 3 9 4

Strona 59 - 51

54 User’s / Programming GuideSymbology IdentifiersYour PSC scanner can be programmed to add and/or change symbol-ogy identifiers which might be requir

Strona 60 - 52 User’s / Programming Guide

06656 55FJ Set Code 39 Symbology IdentifierFK Set I 2/5 Symbology IdentifierFL Set S 2/5 Symbology Identif

Strona 61 - Digit Selection

56 User’s / Programming GuideTo find the hexadecimal values for the characters turn to the Hexa-decimal Conversion Table. The procedure for selecting

Strona 62 - Symbology Identifiers

06656 57 Table 5. Symbology IdentifiersSymbologyZA-PSC DefaultPC-ICL 9518 CCDUPC-Ad A AUPC-Ed E CEAN-8d FF

Strona 63 - 55

58 User’s / Programming GuideWand Emulation ParametersSelect Code TypeScan Option CC if you intend to operate the scanner in Same Code Wand Emulation

Strona 64 - 56 User’s / Programming Guide

06656 59YB 10 inches per second#YC 15 inches per secondYD 20 inches per secondYE 30 inches per secondYF 50

Strona 65 - 57

60 User’s / Programming GuideData SynchronizationYour PSC scanner can be prepared to synchronize the transmission of scanned data to the timing sequen

Strona 66 - Wand Emulation Parameters

06656 61XE Active # Polarity HighXF Active Polarity Low

Strona 67 - 59

06656 iiiMemory ModuleSetup ... 63Marker Beam ...

Strona 68 - Data Synchronization

62 User’s / Programming GuideMemory ModuleThe Memory Module option is a factory installed feature that is requested at time of order. The Memory Modul

Strona 69 - 61

06656 63SetupNC Disable Memory Module*#ND Enable Memory ModuleZK Send Memory ModuleZL Clear Memory ModuleM

Strona 70 - Memory Module

64 User’s / Programming GuideMarker BeamThe Marker Beam feature provides the user with a spotter beam for improved aiming at distant bar code labels a

Strona 71 - 63

06656 65 300 ms 50 MS 350 MS 100 MS 400 MS 150 MS 450 MS 200 MS 500 MS 250 MS

Strona 72 - Marker Beam

66 User’s / Programming GuideScanner LabelingThe PSC Laser Scanners use a low-power, visible laser diode. As with any bright light source, such as the

Strona 73 - 65

06656 67MaintenancePSC Scanners are designed to provide trouble-free operation throughout their lives. The

Strona 74 - Scanner Labeling

68 User’s / Programming GuideTechnical SupportPSC Website SupportThe PSC website (www.psc.com) is the complete source for technical support and inform

Strona 75 - Inspection

06656 69Appendix AHexadecimal Conversion TableTo use the conversion table:1. Find each ASCII character in

Strona 76 - Technical Support

70 User’s / Programming GuideHexadecimal Conversion TablePart A0123456701230123NULSOHSTXETXDLEDC1DC2DC3SP!“#01234567EOTENQACKBELDC4NAKSYNETB$%&‘45

Strona 77 - Appendix A

06656 71Hexadecimal Conversion TablePart B89ABCDEF45670123@ABCPQRS‘abcpqrs4567DEFGTUVWdefgtuvw89ABHIJKXYZ[

Strona 78 - 70 User’s / Programming Guide

iv User’s / Programming GuideNOTES

Strona 79 - 71

72 User’s / Programming GuidePrimary Function Key TableASCII HEX FUNCTIONNUL 00 CONTROL@SOH 01 CONTROL ASTX 02 CONTROL BETX 03 CONTROL CEOT 04 CONTROL

Strona 80 - 72 User’s / Programming Guide

06656 73Secondary Function Key TablesPC/AT, PC/XT, IBM 3151, and IBM PS/2 Model 57/25NOTE 1: [+] right ke

Strona 81 - 73

74 User’s / Programming GuideSecondary Function Key TablesIBM 3171/3181/3191 and IBM 3477ASCII HEX FUNCTIONNUL 00 ESCAPESOH 01 ON LINE ENTER (Make/Bre

Strona 82 - 74 User’s / Programming Guide

06656 75VT220/320/420ASCII HEX FUNCTIONNUL 00‘~ (terminal may be configured for ESCAPE)SOH 01 NEW LINE ENT

Strona 83 - 75

76 User’s / Programming GuideApple MacIntoshASCII HEX FUNCTIONNUL 00 NULSOH 01 F1STX 02 F2ETX 03 F3EOT 04 F4ENQ 05 F5ACK 06 F6BEL 07 F7BS 08 F8HT 09 T

Strona 85 - 77

78 User’s / Programming GuideNOTES

Strona 86 - 78 User’s / Programming Guide

DECLARATION OF CONFORMITYPSC hereby declares that the Equipment specified below has been tested and found compliant to the following Directives and St

Strona 87

Asia PacificPSC Hong KongHong KongTelephone: [852]-2-584-6210Fax: [852]-2-521-0291AustraliaPSC Asia Pacific Pty Ltd.North Ryde, AustraliaTelephone: [

Strona 88

06656 1IntroductionKeyboard Wedge ModeAs a keyboard wedge interface, the PSC scanner can be used with ter-

Komentarze do niniejszej Instrukcji

Brak uwag